The CADD-Solis pump is a versatile ambulatory infusion device designed for safe medication delivery, offering continuous and PCA modes with easy operation and security features․
Overview and History
The CADD-Solis pump, developed by Smiths Medical, is a cutting-edge ambulatory infusion pump designed for safe and efficient medication delivery․ It has a long history of innovation, building on the legacy of the CADD product line․ The pump supports various infusion therapies, including continuous, intermittent, and patient-controlled modes․ Known for its user-friendly interface and advanced security features, the CADD-Solis pump is widely used in both hospital and outpatient settings․ Its development reflects a commitment to improving patient care and clinician usability, making it a trusted choice in infusion therapy․ The pump’s evolution has incorporated feedback from healthcare professionals, ensuring it remains a reliable and versatile solution for modern medical needs․
Safety Features
The CADD-Solis pump is equipped with robust safety features to ensure patient protection and prevent adverse events․ It includes advanced alarms for air detection, occlusions, and low battery warnings․ The pump also incorporates secure programming with multiple security codes to prevent unauthorized access․ Additionally, the autolock feature automatically locks the keypad after a period of inactivity, reducing the risk of accidental changes․ The system is designed to alert users to potential issues, such as upstream occlusions, ensuring timely intervention․ These features collectively enhance the safety and reliability of the pump, making it a dependable choice for critical infusion therapies in various clinical settings․
Intended Use
The CADD-Solis pump is designed for ambulatory infusion therapy, suitable for administering medications in various settings, including hospitals and outpatient care․ It is indicated for intravenous, intra-arterial, subcutaneous, and epidural infusions, among others․ The pump supports continuous infusion, intermittent bolus delivery, and patient-controlled analgesia, catering to diverse therapeutic needs․ Its portability and ease of use make it ideal for patients requiring ongoing medication outside traditional clinical environments․ Healthcare professionals can confidently use the CADD-Solis pump to deliver precise and reliable therapy, ensuring optimal patient outcomes across multiple infusion types and clinical applications․
Technical Specifications
The CADD-Solis pump features models like 2110 with software version 4․3, supporting mL, mg, and mcg measurements․ It offers continuous, bolus, and PCA delivery modes, with programming in 0․1 increments and delivery limits based on max doses per hour․
Pump Models
The CADD-Solis pump is available in multiple models, including the 2110 and 2120, designed for ambulatory infusion therapy․ Model 2110 operates with software version 4․3, offering precise medication delivery․ The 2120 model, as detailed in the operator’s manual, supports advanced features like wireless communication․ Both models are lightweight and portable, suitable for continuous, intermittent, or PCA delivery․ They are designed for intravenous, subcutaneous, and epidural infusions, ensuring versatile clinical applications․ The pumps feature user-friendly interfaces and robust security settings to prevent unauthorized access․ Their compact design and long battery life make them ideal for patient mobility․ These models are widely used in both hospital and outpatient settings, providing reliable and safe medication administration․
Software Versions
The CADD-Solis pump operates on specific software versions, such as version 4․3 (Software package 97-0582-0403XX-01), ensuring compatibility with various clinical applications․ Regular updates enhance functionality, security, and user experience․ Clinicians can access updated software through Smiths Medical support․ The software manages medication libraries, delivery modes, and security settings․ It supports programming in milliliters, milligrams, or micrograms, with precise increments for accurate dosing․ The software also enables alarms, troubleshooting, and data logging․ Each version is tested for reliability, ensuring safe and effective infusion therapy․ Proper software installation is crucial for optimal pump performance and patient safety․ Always consult the operator’s manual for specific software requirements and update instructions․ This ensures the pump functions correctly and adheres to clinical guidelines․
Compatibility
The CADD-Solis pump is compatible with a range of infusion therapies and accessories, ensuring versatile use in clinical settings․ It works seamlessly with Smiths Medical-approved administration sets and cassettes, including those with anti-siphon valves․ The pump is designed to integrate with various medication delivery systems, supporting intravenous, subcutaneous, and epidural infusions․ Compatibility with specific software versions ensures optimal performance and safety․ Only authorized Smiths Medical accessories should be used to maintain proper function and avoid potential issues․ The pump’s compatibility extends to multiple delivery modes, including continuous and intermittent infusions, making it suitable for diverse patient needs․ Always consult the manual for specific compatibility details to ensure safe and effective operation․ Proper pairing of accessories is crucial for reliable medication delivery․
Operating the Pump
The CADD-Solis pump is powered on by pressing and holding the power switch․ Use the keypad to navigate menus and settings; The green light indicates normal operation, while amber signals alarms or issues․ Always confirm settings before starting delivery․
Powering On/Off
To power on the CADD-Solis pump, press and hold the power switch until the display activates․ The green light indicates normal operation, while amber signals alarms or low battery․ To turn off, press the switch and confirm shutdown․ Always ensure the pump is off before replacing batteries or disconnecting from power․ Use the AC adapter for charging when not in use․ Proper power management ensures reliable operation and patient safety․ Follow manual guidelines for power-related tasks to avoid malfunctions․ Always verify the pump’s status before starting or stopping infusion therapy․
Navigating the Interface
The CADD-Solis pump features an intuitive interface with a clear display and keypad for easy navigation․ The display shows current settings, status indicators, and alarms․ Use the up and down arrows to scroll through menus and select options․ The select button confirms choices, while the stop/start button controls infusion․ The home screen provides quick access to key functions, and menus are organized for clarity․ The display also shows battery life, reservoir volume, and delivery mode indicators․ Navigation is straightforward, allowing clinicians to efficiently program and monitor therapy․ The interface is designed to minimize errors and ensure smooth operation during patient care․ Proper training is essential for optimal use of the pump’s features․ Always refer to the manual for detailed guidance on navigating the interface․
Programming Modes
The CADD-Solis pump offers multiple programming modes to tailor therapy to patient needs․ Continuous infusion delivers medication at a steady rate, while intermittent bolus provides doses at set intervals․ Patient-Controlled Analgesia (PCA) allows patients to self-administer boluses within prescribed limits․ The pump supports manual programming for customized settings, such as dose limits and delivery rates․ Security codes protect programming functions, ensuring only authorized users can modify settings․ The pump also supports protocol libraries, enabling standardized therapy protocols․ Programming can be done via the keypad or through software, ensuring flexibility and precision․ These modes enhance clinical versatility, making the CADD-Solis suitable for diverse infusion therapies․ Always refer to the manual for detailed programming instructions․ Proper training is essential for safe and effective use․
Programming and Configuration
The CADD-Solis pump offers advanced programming and configuration options, including protocol libraries for standardized therapies, manual programming for customized settings, and robust security features to prevent unauthorized changes․
Protocol Libraries
A protocol library in the CADD-Solis pump is a collection of predefined therapy settings, including drug concentrations, delivery rates, and dosing limits, created using CADD-Solis Medication Safety Software․ These libraries streamline programming by allowing clinicians to select standardized protocols, reducing the risk of errors․ Protocols are organized by therapy type, drug, and delivery mode, and can be customized to meet specific patient needs․ Once loaded onto the pump, they guide the setup process, ensuring consistency across treatments․ Security features prevent unauthorized modifications, and libraries can be updated as clinical practices evolve․ This system enhances efficiency and safety in infusion therapy management․ Clinicians can also manually adjust settings if required, ensuring flexibility while maintaining protocol integrity․
Manual Programming
Manual programming on the CADD-Solis pump allows clinicians to customize infusion settings without using protocol libraries․ This mode is ideal for unique patient needs or when predefined protocols are unavailable․ To program manually, the keypad must be unlocked using a security code․ Clinicians can set parameters such as infusion rate, dose limits, and bolus amounts․ The pump guides users through each step, ensuring accurate input․ Once settings are confirmed, the pump begins delivery, providing real-time feedback․ Manual programming offers flexibility but requires careful input to avoid errors․ It is recommended for experienced users, as it bypasses the safeguards of protocol libraries․ This feature is essential for tailored therapy in diverse clinical scenarios․ Proper training is crucial to ensure safe and effective use of manual programming․
Security Settings
The CADD-Solis pump features advanced security settings to prevent unauthorized access․ It uses three distinct security codes: keypad, clinician, and administrator codes․ These codes protect critical functions like programming, starting/stopping infusion, and altering settings․ The keypad automatically locks after 30 seconds of inactivity, reducing the risk of accidental changes․ Clinicians can customize security levels to restrict access based on user roles․ For example, patients and unauthorized staff cannot modify therapy settings without the correct code․ These measures ensure that only trained professionals can adjust pump configurations, enhancing patient safety․ Proper use of security settings is vital to maintain the integrity of infusion therapy and prevent potential errors․
Delivery Modes
The CADD-Solis pump supports Continuous Infusion, Intermittent Bolus, and Patient-Controlled Analgesia (PCA), offering flexible medication delivery options tailored to patient needs․
Continuous Infusion
The CADD-Solis pump offers a Continuous Infusion mode, delivering medication at a steady, pre-programmed rate․ This mode is ideal for therapies requiring consistent drug administration, such as antibiotics or pain management․ Clinicians can set the rate in milliliters (mL), milligrams (mg), or micrograms (mcg) per hour, with increments as precise as 0․1 units․ The pump ensures accurate delivery, minimizing risks of under- or over-infusion․ Before starting, the tubing must be primed to remove air bubbles, and the cassette reservoir should be filled appropriately․ Alarms alert users to issues like air in the line or low battery, ensuring patient safety․ This mode is essential for maintaining therapeutic drug levels continuously, making it a reliable choice for various clinical applications․
Intermittent Bolus
The Intermittent Bolus mode on the CADD-Solis pump allows for scheduled or on-demand medication delivery in fixed doses․ Clinicians can program bolus amounts and intervals, ensuring precise dosing․ This mode is ideal for therapies requiring periodic medication spikes, such as pain relief․ The pump supports bolus doses in milliliters (mL), milligrams (mg), or micrograms (mcg), with delivery limits set to prevent over-administration․ The lockout period prevents multiple doses within a specified timeframe․ Alarms alert users to issues like air in the line or low battery, ensuring safe operation․ This mode is versatile, supporting various clinical applications while maintaining patient safety and therapeutic efficacy․ It is particularly useful for managing conditions requiring intermittent therapy, enhancing patient comfort and care․
Patient-Controlled Analgesia
Patient-Controlled Analgesia (PCA) on the CADD-Solis pump empowers patients to self-administer pain relief within set limits; Clinicians can configure bolus doses, lockout intervals, and delivery limits to ensure safety․ The pump’s PCA mode combines continuous basal rates with on-demand boluses, providing personalized pain management․ Patients can trigger doses via a remote control, enhancing comfort and autonomy․ Security settings prevent unauthorized changes, and alarms notify healthcare providers of issues like low reservoir volume or air in the line․ This mode is ideal for post-operative care or chronic pain management, offering flexibility and precision while maintaining patient safety and therapeutic efficacy․ It promotes patient satisfaction by allowing them to manage their pain effectively․
Alarms and Troubleshooting
The CADD-Solis pump features alarms for issues like air in the line or low battery․ Resolving these involves acknowledging the alarm, addressing the cause, and restarting delivery to ensure proper operation and patient safety․
Common Alarms
The CADD-Solis pump alerts users through visual and audible alarms for critical conditions․ Common alarms include low battery, reservoir volume low, or air in the line․ The amber light flashes during alarms, and specific messages appear on the screen․ For example, a “Reservoir Volume Low” alarm indicates medication is nearing depletion, while an “Air in Line” alarm signals air bubbles in the tubing, requiring immediate attention․ These alerts ensure prompt resolution to maintain safe and accurate medication delivery․ The pump also provides clear instructions for addressing each issue, minimizing downtime and ensuring patient safety․ Properly responding to alarms is essential for effective operation and therapy continuation․
Resolving Air in Line Alarm
To resolve the Air in Line alarm on the CADD-Solis pump, follow these steps: First, press Acknowledge to clear the alarm․ Then, close the clamps and disconnect the fluid path from the patient to inspect for air bubbles․ Prime the tubing to remove any air by cycling fluid through it․ Once the line is clear, reconnect it to the patient and restart delivery․ Ensure no air remains before resuming operation to prevent complications․ Proper priming and checking for bubbles are crucial to avoid medication delivery issues or potential patient harm․ Always refer to the manual for detailed guidance on handling such alarms effectively․
General Troubleshooting Tips
For general troubleshooting of the CADD-Solis pump, start by ensuring the device is properly powered on and batteries are charged․ Check for loose connections, especially the cassette and tubing, and verify that all clamps are fully closed․ Review the programming settings to ensure accuracy and consult the manual for guidance․ If issues persist, reset the pump or contact Smiths Medical customer support․ Always follow proper cleaning and maintenance procedures to prevent malfunction․ Regularly inspect the pump for damage and ensure only authorized accessories are used․ Refer to the troubleshooting section in the manual for specific solutions to common errors, and never attempt repairs without proper training․
Maintenance and Accessories
Regularly clean the CADD-Solis pump with a damp cloth and avoid harsh chemicals․ Replace batteries as needed and use only authorized Smiths Medical accessories for optimal performance․
Cleaning the Pump
Regular cleaning of the CADD-Solis pump is essential for maintaining functionality and patient safety․ Use a soft, damp cloth to wipe the exterior, avoiding harsh chemicals or abrasive materials․ Do not submerge the pump in water or expose it to excessive moisture․ For the blue cap on the IV line, scrub with an alcohol pad for 15 seconds and allow it to air dry․ Ensure all surfaces are dry before reuse to prevent damage or bacterial growth․ Cleaning should be performed by authorized personnel following the manufacturer’s guidelines to ensure the pump remains in optimal working condition․
Replacing Batteries
The CADD-Solis pump operates on a rechargeable battery and AA alkaline or lithium batteries․ To replace the batteries, ensure the pump is turned off․ Insert the AA batteries into the battery compartment, following the polarity markings․ For the rechargeable battery, connect the AC adapter to the power jack and charge for 12-14 hours initially․ The pump can operate for up to 42 hours on a full charge․ Avoid using damaged batteries or mixing old and new ones, as this may affect performance․ Always follow proper disposal guidelines for used batteries․ Regular battery maintenance ensures reliable operation and patient safety․
Compatible Accessories
The CADD-Solis pump supports a range of accessories to ensure optimal functionality․ These include medication cassettes, tubing sets, and power adapters․ The pump is compatible with Smiths Medical-branded accessories, which are specifically designed for seamless operation․ Using non-recommended accessories may compromise pump performance or safety․ For example, the CADD medication cassette reservoir and anti-siphon valves are essential for accurate drug delivery․ The pump also supports USB connectivity for data transfer and software updates․ Accessories can be obtained through Smiths Medical Customer Service․ Always refer to the manual for a full list of compatible items to maintain safety and effectiveness․ Using genuine parts ensures compliance with regulatory standards and optimal patient care․ Proper selection of accessories is critical for reliable pump operation․
Safety Precautions
Always inspect the CADD-Solis pump for damage before use․ Do not use a damaged pump, as it can compromise safety and proper function․ Follow manual guidelines for handling and operation to ensure patient safety and prevent adverse events․
Contraindications
The CADD-Solis pump should not be used if it is damaged, dropped, or malfunctioning․ Do not use the pump if there is evidence of physical damage or improper function․ Always ensure the pump is inspected before use to avoid potential safety risks․ Contraindications include situations where the pump’s integrity is compromised, such as cracks, broken parts, or exposure to excessive force․ If the pump is damaged, do not attempt to operate it, as this could lead to inaccurate medication delivery or patient harm․ Contact Smiths Medical Customer Service for assistance with damaged or non-functioning pumps․ Proper inspection and maintenance are critical to ensuring safe and effective operation․
Cautions
Use only Smiths Medical-authorized accessories with the CADD-Solis pump to prevent operational issues․ Always prime the tubing with the pump disconnected from the patient to avoid air embolism risks․ Do not disclose security codes to unauthorized individuals, as this could compromise safe operation․ Regularly inspect the pump and tubing for signs of wear or damage․ Avoid exposing the pump to extreme temperatures or moisture․ Ensure proper training is provided to healthcare professionals and patients to prevent misuse․ Follow all guidelines for battery replacement and charging to maintain functionality․ Adhere to the manufacturer’s instructions for all aspects of pump operation and maintenance to ensure patient safety and accurate medication delivery․
Handling Damaged Pumps
If the CADD-Solis pump is dropped, inspect it for damage․ Do not use a pump that is damaged or malfunctioning․ Immediately discontinue use and notify a healthcare professional․ Contact Smiths Medical Customer Service to return the pump for evaluation or repair․ Damaged pumps must only be serviced by authorized personnel to ensure safety and compliance․ Properly dispose of any irreparably damaged pumps according to local regulations and environmental guidelines․ Never attempt to repair the pump yourself, as this could lead to further damage or safety risks․ Always follow the manufacturer’s instructions for handling and returning damaged devices to maintain patient safety and device integrity․
Clinical Applications
The CADD-Solis pump is used for various infusion therapies, including intravenous, subcutaneous, and epidural delivery, ensuring precise medication administration in both hospital and outpatient settings․
Approved Infusion Types
The CADD-Solis pump supports a wide range of infusion types, including intravenous, intra-arterial, subcutaneous, and epidural delivery․ It is also approved for use in intraoperative sites, such as soft tissue or surgical wounds, and for regional anesthesia․ The pump can deliver medication into the subarachnoid space or epidural area for pain management․ Additionally, it is suitable for intra-peritoneal and close proximity nerve infusions․ These versatile applications make it a reliable choice for various clinical settings, ensuring precise and safe medication delivery․ Always use the pump in accordance with clinical guidelines and under the supervision of a qualified healthcare professional․
Medication Delivery
The CADD-Solis pump delivers medication with precision, supporting continuous infusion, bolus doses, and patient-controlled analgesia (PCA)․ It allows programming in milliliters (mL), milligrams (mg), or micrograms (mcg), with adjustable delivery limits and clinician bolus settings․ The pump ensures accurate and consistent medication administration, with options for setting maximum doses per hour․ Clinicians can customize delivery parameters to meet patient needs, while security features prevent unauthorized changes․ The pump also supports multiple therapies, including intermittent boluses and continuous rates, making it versatile for various treatment plans․ Its advanced design ensures safe and efficient medication delivery in both hospital and outpatient settings, with clear alarms and troubleshooting guidance to maintain optimal performance․
User Manuals and Resources
Downloadable PDF manuals for the CADD-Solis pump provide detailed instructions for operation, programming, and troubleshooting․ Manufacturer support is also available for additional assistance and resources․
Downloadable Guides
Downloadable PDF manuals for the CADD-Solis pump are available, offering comprehensive instructions for operation, programming, and troubleshooting․ These guides include detailed sections on setting up the pump, priming the tubing, and resolving alarms․ Additionally, the manuals cover security settings and protocol libraries, ensuring safe and effective use․ Clinicians can access step-by-step instructions for manual programming and customizing delivery modes․ The guides also provide information on compatible accessories and maintenance tips․ Users are advised to refer to the latest version of the manual for updated features and technical specifications, ensuring optimal performance of the CADD-Solis pump․
Manufacturer Support
Smiths Medical offers comprehensive support for the CADD-Solis pump, including technical assistance and customer service․ Users can access updated manuals, training resources, and troubleshooting guides through their official website․ The manufacturer provides detailed contact information for inquiries, ensuring prompt resolution of issues․ Additionally, Smiths Medical offers 24/7 support for urgent matters, guaranteeing uninterrupted patient care․ Regular updates and maintenance information are also available to ensure the pump operates at its best․ This dedicated support system underscores Smiths Medical’s commitment to user satisfaction and patient safety with the CADD-Solis pump․